Pharma gradeDouble-Pass RO
EDI Ultrapure Water System
Electrodeionisation after double-pass RO for 10–18 MΩ·cm water without chemical regeneration — the standard package for pharmaceutical and…
View detailsDouble-Pass RO
Two-stage reverse osmosis for conductivity below 5 µS/cm — the standard choice for pharmaceutical, electronics and food-grade process water.
Double-pass RO runs the permeate of the first RO stage through a second membrane array. The result is a consistent conductivity of 1–5 µS/cm with very low silica and TOC, without the cost of EDI.
| Model | ZC-DPRO-5 |
|---|---|
| Capacity | 0.5–20 m³/h |
| Recovery rate | 55–70% |
| Salt rejection | ≥ 99.5% (two stage) |
| Installed power | 3–30 kW |
| Power supply | 380V / 50Hz / 3Ph (or to client standard) |
| Frame / wetted material | SS304 / SS316L sanitary option |
| Membrane | Dow BW30-4040 / BW30-8040 |
| Warranty | 24 months |
| Lead time | 25–35 days |
| Product conductivity | 1–5 µS/cm |
| Feed water | Municipal / softened, SDI < 5 |
| Pretreatment | Multimedia + softener + 5 µm |
| Control | PLC with conductivity trending |
Specifications are indicative. Final design is confirmed against your water analysis and site conditions.
Start with your water analysis
Our engineers reply within 12 working hours with a preliminary process design, equipment list and budget range.